Our state of the art Datacentre facility was built with reliability, redundancy & resiliency in mind. By building the Datacentre from the ground up with these directives, using only the highest quality & proven technology, we have created a facility that ensures military level ‘mission critical’ uptime & redundancy. This means reliability that you & your end-users can bank on.

Datacentre Features

  • Security mesh, reinforced door frames, walls & ceilings at all entry points
  • Man-trap entry, monitored proximity card access & personnel control
  • 24x7x365 Video surveillance & remote monitoring throughout
  • Dual path 24/7/365 monitored alarm & glass break
  • On site computer service room with hot swap spares for same day repairs
  • Monitored VESDA (very early smoke detection apparatus) system with 3-stage alarms.
  • In-house carbon dioxide extinguishers.
  • 1.28 PUE Certification

Power Infrastructure

  • Power security: “A”, “B” & “C” power feed options per rack
  • 1x or upto 8x 16A or 1x or upto 8x 32A feeds per rack
  • Secured, standby 500KvA 2506 Perkins diesel generator, housed inside the facility (on 24/7 SLA for repairs & refueling)
  • Our generator can power the entire datacentre indefinitely
  • Three in-line UPS power conditioners, isolation transformers
  • Monthly routine systems testing and maintenance

Connectivity & Bandwidth

  • Carrier Neutral Connectivity (Chorus, Vector, Vodafone, Telstra)
  • 24/7/365 network monitoring by our (NOC)
  • 10GbE wire-speed core network access
  • Domestic peering for high speed traffic delivery within New Zealand
  • Fibre carriers all have multiple redundant paths of fibre entering the datacentre from different ducts
  • Strict cabling standards have been uniformly utilised using T568B configuration
  • Carrier Neutral Peering, we have a large list of ISP’s who can service your equipment from inside HD

Air Conditioning

  • We have three fully redundant and intelligent HVAC CRAC units with POD based temperature monitoring & flow control with micro particle air filtration
  • We support Blade systems, A maximum of 20kw per rack
  • The Datacentre operates using strict thermal guidelines for data processing environments. temperature is 21 °C & a humidity of 49% with a maximum dew point of 15°C

Access

  • You can access your rack at anytime without charge 24x7x365
background


Attention to detail in terms of power, cooling and connectivity means your servers housed in our facility last longer...